http://www.chillventa.de/de/besucher/
Promotor VerlagPromotor VerlagPromotor Verlag
Anzeigen
Dezentrale Lüftungssysteme
Differenzdrucksysteme
Energieeffizienz
Frequenzumrichter
Gebäudeautomation
Hocheffiziente Energieeinsparung
Küchenlüftung
Kühldeckensysteme
Kaltwassersätze
Kaltwassersätze
Luftschleier
TGA-Software
VRF-Buch

VRF-Klima –
die stille Revolution

"Das Prinzip, mit einem zentralen Außengerät über einen Kältemittel
kreislauf viele Raum-
Innengeräte mit thermischer Leistung zu versorgen, hat den Markt leise erobert."

1. Auflage 2009
Promotor Verlag
47,00 Euro
Ihre Ansprechpartner
 
Regina Metz

Tel. 0721-565 14 14
 
Marion Burst

Tel. 0721-565 14 23
 
Standard 62.2-2007 - Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
Seitenzahl: 20
Erscheinungsjahr: 2007
ISSN 1041-2336
ca. 60,00 Euro

Unser Tipp:
auch direkt bei ASHRAE als Download erhältlich

Inhalt:

(Supersedes ANSI/ASHRAE Standard 62.2-2004) Includes ANSI/ASHRAE addenda listed in Appendix C

1. PURPOSE
This standard defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality (IAQ) in low-rise residential buildings.

2. SCOPE
This standard applies to spaces intended for human occupancy within single-family houses and multifamily structures of three stories or fewer above grade, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails.

2.1
This standard considers chemical, physical, and biological contaminants that can affect air quality. Thermal comfort requirements are not included in this standard (see ANSI/ ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy).

2.2
While acceptable indoor air quality is the goal of this standard, it will not necessarily be achieved even if all requirements are met

a. because of the diversity of sources and contaminants in indoor air and the range of susceptibility in the population;
b. because of the many other factors that may affect occupant perception and acceptance of IAQ, such as air temperature, humidity, noise, lighting, and psychological stress;
c. if the ambient air is unacceptable and this air is brought into the building without first being cleaned (cleaning of ambient outdoor air is not required by this standard);
d. if the systems are not operated and maintained as designed; or
e. when high-polluting events occur.

2.3
This standard does not address unvented combustion space heaters. Preview this standard!

Promotor Verlags- und Förderungsgesellschaft mbH
Postfach 21 10 53 D-76160 Karlsruhe • Borsigstr. 3 D-76185 Karlsruhe
Fon +49 (0)7 21 / 5 65 14 - 0 • Fax -35 •



Zur Planung einer zentralen Klimaanlage gemäß DIN EN 13779 können Sie auf die Ermittlung des ODA-Werts (ODA = Outdoor Air) nicht verzichten.
Die Erstauskunft kostet bei uns nur 49 Euro.
-> mehr Infos
-> Mustergutachten
bestellen
Pollution-Info
in Kooperation mit cci Promotor