http://www.samson.de
Promotor VerlagPromotor VerlagPromotor Verlag
Anzeigen
Frequenzumrichter
Energieeffizienz
Gebäudeautomation
Dezentrale Lüftungssysteme
Küchenlüftung
Kühldeckensysteme
Kaltwassersätze
Kaltwassersätze
Hocheffiziente Energieeinsparung
Differenzdrucksysteme
Luftschleier
Brandschutz
Quenzel, Karl-Heinz

Einrichtungen zur Rauch- und Wärmefreihaltung
Praxis für Architekten, Planer und Fachfirmen


4., überarbeitete Auflage Juli 2009


79,00 Euro (+Versand)
Kälte-/Klimatechnik
Rietschel, H./ Fitzner, Klaus (Hrsg.)

Raumklimatechnik
Band 2: Raumluft- und Raumkühltechnik


16. völlig überarbeitete und erweiterte Auflage 2008


199,95 Euro (+Versand)
Ihre Ansprechpartner
 
Regina Metz

Tel. 0721-565 14 14
 
Marion Burst

Tel. 0721-565 14 23
 
 
2009 Handbook - Fundamentals (S-I)
(the companion CD includes SI and Inch-Pound editions)
Units: I-P
ca. 220,00 Euro

Inhalt:

The 2009 ASHRAE Handbook—Fundamentals covers basic principles and data used in the HVAC&R industry. Updated with research sponsored by ASHRAE and others, this volume includes 1,000 pages and 39 chapters covering general engineering information, basic materials, climate data, load and energy calculations, duct and pipe design, and sustainability, plus reference tables for abbreviations and symbols, I-P to SI conversions, and physical properties of materials. An accompanying CD-ROM (free with the book—also sold separately) contains all the volume’s chapters in both I-P and SI units.

The 2009 ASHRAE Handbook—Fundamentals covers basic principles and data used in the HVAC&R industry. The ASHRAE Technical Committees that prepare these chapters strive not only to provide new information, but also to clarify existing information, delete obsolete materials, and reorganize chapters to make the Handbook more understandable and easier to use. An accompanying CD-ROM contains all the volume’s chapters in both I-P and SI units.

This edition includes a new chapter (35), Sustainability, which defines this concept for HVAC&R and describes the principles, design considerations, and detailed evaluations needed in designing sustainable HVAC&R systems.

In this volume, chapter order and groupings have been revised for more logical flow and use. Some of the other revisions and additions to the volume are as follows:

  • Chapter 1, Psychrometrics, has new information on the composition of dry air, and revised table data for thermodynamic properties of water and moist air.
  • Chapter 6, Mass Transfer, has added examples on evaluating diffusion coefficients, and on heat transfer and moisture removal rates.
  • Chapter 7, Fundamentals of Control, includes new content on dampers, adaptive control, direct digital control (DDC) system architecture and specifications, and wireless control.
  • Chapter 9, Thermal Comfort, has a new section on thermal comfort and task performance, based on multiple new studies done in laboratory and office environments.
  • Chapter 10, Indoor Environmental Health, was reorganized to describe hazard sources, health effects, exposure standards, and exposure controls. New and updated topics include mold, Legionella, indoor air chemistry, thermal impacts, and water quality standards.
  • Chapter 14, Climatic Design Information, has new climate data for 5564 stations (an increase of 1142 new stations compared to 2005 Fundamentals) on the CD-ROM accompanying this book. A subset of data for selected stations is also included in the printed chapter for convenient access.
  • Chapter 15, Fenestration, has been revised to include new examples of solar heat gain coefficient (SHGC) calculations, and new research results on shading calculations and U-factors for various specialized door types.
  • Chapter 16, Ventilation and Infiltration, has new, detailed examples, updates from ASHRAE Standards 62.1 and 62.2, discussion of relevant LEED® aspects, and new information on airtightness and ventilation rates for commercial buildings.
  • Chapter 18, Nonresidential Cooling and Heating Load Calculations, has been updated to reflect new ASHRAE research results on climate data and on heat gains from office equipment, lighting, and commercial cooking appliances.
  • Chapter 20, Space Air Diffusion, has been completely rewritten to harmonize with related chapters in other volumes, with major sections on fully mixed, partially mixed, stratified, and task/ambient systems and the principles behind their design and operation.
  • Chapter 21, Duct Design, has new data for round and rectangular fittings in agreement with the ASHRAE Duct Fitting Database, as well as new content on duct leakage requirements, spiral duct roughness, and flexible duct pressure loss correction.
  • Chapter 23, Insulation for Mechanical Systems, has added tables from ASHRAE Standard 90.1-2007, and a new section on writing specifications.
  • Chapter 24, Airflow Around Buildings, has added a detailed discussion on computational evaluation of airflow, plus new references including updated versions of design standards and manuals of practice.
  • Chapters 25, 26, and 27 carry new titles, reorganized as chapters on Heat, Air, and Moisture Control Fundamentals, Material Properties, and Examples, respectively, with updated content throughout.
  • Chapter 29, Refrigerants, has new content on stratospheric ozone depletion, global climate change, and global environmental characteristics of refrigerants.
  • Chapter 30, Thermophysical Properties of Refrigerants, has updated data for R-125, R-245fa, R-170, R-290, R-600, and R-600a.
  • Chapter 36, Measurement and Instruments, has revised content on measurement of air velocity, infiltration, airtightness, and outdoor air ventilation, plus new information on particle image velocimetry (PIV) and data acquisition and recording.


This volume is published, both as a bound print volume and in electronic format on a CD-ROM, in two editions: one using inch-pound (I-P) units of measurement, the other using the International System of Units (SI).

Keywords:

fundamentals, handbook, guide, basics, principles, design, hvac, hvacr, psychrometrics, thermodynamics, refrigeration, refrigeration cycles, fluid flow, heat flow, two-phase flow, mass transfer, control, sound, vibration, thermal comfort, comfort, ieq, iaq, health, indoor health, indoor environmental health, air contaminant, pollutant, odors, iem, indoor environmental modeling, modeling, climatic design information, climate data, weather data, climate information, fenestration, windows, ventilation, infiltration, load calculation, energy calculation, residential, nonresidential, energy estimating, energy modeling, space air diffusion, ducts, duct design, pipe sizing, piping, insulation, mechanical insulation, airflow, buildings, envelope, building envelope, heat control, air control, leakage control, leakage, infiltration, exfiltration, moisture control, vapor control, vapor retarder, air barrier, airflow retarder, combustion, fuels, refrigerant, thermophysical properties, materials, brine, secondary coolant, coolant, sorbent, dessicant, physical properties, energy, energy resources, sustainability, green design, conservation, measurement, instruments, abbreviations, symbols, conversions, units, codes, standards
Promotor Verlags- und Förderungsgesellschaft mbH
Postfach 21 10 53 D-76160 Karlsruhe • Borsigstr. 3 D-76185 Karlsruhe
Fon +49 (0)7 21 / 5 65 14 - 0 • Fax -35 •



Zur Planung einer zentralen Klimaanlage gemäß DIN EN 13779 können Sie auf die Ermittlung des ODA-Werts (ODA = Outdoor Air) nicht verzichten.
Die Erstauskunft kostet bei uns nur 49 Euro.
-> mehr Infos
-> Mustergutachten
bestellen
Pollution-Info
in Kooperation mit cci Promotor